The depyrogenation tunnel designed to reduce the endotoxin at least 3 log and reduce the bacteria at least 6 log.
• Modular design, each is one independent unit.
• The inner chamber is fully welded, and the expansion joint is used between the chambers to prevent cracking.
• Heat penetration effect FH≥30min,based on T0=250℃,Z=46.4℃.
• Endotoxin ≤0.1EU, ensure endotoxin at least 3log drop and bacteria at least 6log log drop.
• Temperature uniformity can be achieved ±5℃, air velocity uniformity can be achieved ±20%
• △P≥10Pa between tunnel inside and cleaning room is possible.
• Negative pressure seal for HEPA
• The fan driver adopts self-cooling mode without additional cooling medium
• Equipped with air pressure balance system in order to ensure the pressure is stable.
• CIP is option for conveyor belt.
• SIP is option for cooling zone.
• The sealing door is option to separate completely the cooling zone and aseptic area.
• Wide vial application from 2ml ~ 100ml.
Main Technical Data
| Model | APV2SW050 | APV2SW100 | APV2SW200 | APV2SW300 | APV2SW400 | APV2SW500 | |
|---|---|---|---|---|---|---|---|
| Container Range (ml) | 2-100 | 2-100 | 2-100 | 2-100 | 2-100 | 2-100 | |
|
Capacity (VPM) |
10ml (φ22mm) |
50 | 100 | 200 | 300 | 400 | 500 |
| Purified Water Supply (m³/h) | 0.3 | 0.4 | 0.6 | 0.6 | 0.6 | 0.8 | |
| Chilled Water Supply (m³/h) | 1.5-2.5 | 4-6 | 5-7 | 7-10 | 7-10 | 10-14 | |
| Compressed Air for control Supply(m³/h) | 3 | 3 | 3 | 3 | 3 | 3 | |
| Process Compressed Air Supply(m³/h) | 15 | 15 | 15 | 15 | 15 | 18 | |
| Air Supply of Infeed Zone (m³/h) | 900-1300 | 1400-1800 | 1500-2000 | 1500-2000 | 1500-2000 | 1760-2350 | |
| Air Supply of Heating Zone (m³/h) | 100-200 | 200-400 | 300-500 | 300-500 | 300-500 | 470-705 | |
| Normal Power (kw) | 40 | 72 | 85 | 108 | 130 | 148 | |
| Dimension L*W*H (mm) | 2545*1655*2407 | 3168*1825*2407 | 3808*2075*2464 | 4117*2075*2464 | 5273*2075*2464 | 5467*2225*2464 | |
| Weight (kg) | 3500 | 4000 | 4800 | 5500 | 7000 | 8500 | |